*(1) 5 Zone Outdoor Unit 48,000Btu (20.5 SEER
)

DLCMRA Features Include:

Heats
& Cools (-22F/-13F)Basepan Heater (Built in)
Gold Coated Coils7yr Compressor 5yr Parts Warranty
Specifications
Brochure
AHRI


*
(2) Indoor Units 24000 Btu Indoor Unit (DLFSA)
DLFSAAH24XAK
DLFSA Features Include:

FEATURES
Modes: Cool, Heat, Dry, Fan, Auto 
Multi Poise Installation (Up Flow, Down Flow, Horizontal Right, Horizontal Left)
Total system static pressure up to 0.8 in. W.C
Less than 2% air leakage
Quiet indoor operation 
Anti-corrosive fin coating 
Optional Electric Heat Packages available (5kw and 10kw)
Built-in third-party thermostat compatibility (Single Stage): Not Included.
Specifications  
Brochure

Warranty Card


____________________________________________________________
Installation Kits are not included, please see the dropdown boxes above for those options.
_______________________________________________________________________


 
Midea Series is Energy Saving
DC Inverter 180 degree Sine Wave, Super DC Inverter Air Conditioner adopts the advanced 180 degree Sine Wave. DC Inverter driving technology and Brushless DC (BLDC) motor (Revolution Variable) compressor. More energy-saving, more consistent and quieter than 120 degree Square Wave DC Inverter.
 
Mini Split Reviews | Compare toHome Depot Mini Splits, Fujistu Mini Splits, Mitsubishi Mini Splits, LG Mini Splits, Samsung Mini Splits, Sanyo Mini Splits, Ramsond Mini Splits, Trane Mini Splits, Panasonic Mini Splits, Lennox Mini Splits, Questside Mini Splits, Daikin Mini Splits, Toshiba Mini Splits, Carrier Mini Splits, Hitachi Mini Splits, Lowes Mini Splits, Gree Mini Splits, Senville Mini Splits, Thermocore Mini Splits  

Outdoor KEY FEATURES

  • Available in 208/230V
  • Connect 2 indoor units
  • Built-in basepan heater
  • Quiet outdoor operation, as low as 62 dB(A)
  • Aluminum Golden Hydrophilic pre-coated fins
  • Cooling operating range -13°~122° F (-25°~50° C)
  • Heating operating range -22°~86° F (-30°~30° C)

Color: Clay

DLCMRA Outdoor Unit
Heat Pump
Size 48
Outdoor Model DLCMRAH48EAK
Performance Ducted
ENERGY STAR® NO
Cooling System Tons 4.0
Cooling Rated Capacity Btu/h 48,000
Cooling Cap. Range Min - Max Btu/h 8,60~52,000
SEER 20.5
EER 10.1
Heating Rated Capacity (47° F) Btu/h 50,000
Heating Maximum Capacity (5° F) Btu/h 36,800
Heating Cap. Range Min - Max Btu/h 6,880~54,050
HSPF 10.1
COP (47° F) W/W 3.4
COP (5° F) W/W 1.8
Operating Range
Cooling Outdoor DB Min - Max ° F (° C) -13~122 (-25~50)
Heating Outdoor DB Min - Max ° F (° C) -22~86 (-30~30)
Piping
Total Piping Length ft (m) 328 (100)
Piping to furthest FCU ft (m) 115 (35)
Drop (OD above ID) ft (m) 65 (20)
Lift (OD below ID) ft (m) 65 (20)
Pipe Connection Size - Liquid in (mm) 1/4*5 (6.35*5)
Pipe Connection Size - Suction in (mm) 1/2 *2+ 3/8*3 (12.7*2+9.52*3)
Refrigerant
Type R410A
Charge lbs (kg) 10.13 (4.6)
Electrical
Voltage-Phase-Cycle V-Ph-Hz 208/230-1-60
Power Supply Indoor unit powered from outdoor unit
MCA A 35
MOCP - Fuse Rating A. 50
Outdoor
Unit Width in (mm) 41.15 (1045)
Unit Height in (mm) 52.48 (1333)
Unit Depth in (mm) 17.63 (448)
Net Weight lbs (kg) 223.8 (101.5)
Airflow CFM 4,500
Sound Pressure dB(A) 64

          
INDOOR KEY FEATURES
  • Installation Flexibility
    A built-in secondary drain allows the unit to be mounted vertically (up flow or down flow) or horizontally (left or right), enabling multi-position installation. All three sizes are capable of operating as traditional central ducted systems when paired with a compatible single zone outdoor unit.  
  • Efficient Comfort
    As an alternate to gas furnaces, reduce the use of fossil fuels and experience cleaner energy and efficiency levels that meet many local and federal requirements.
  • CONTROLS: Factory installed 24V interface for third-party thermostat compatibility* (*Wired thermostat not included)
  • Indoor copper connections require brazing, while outdoor connections are standard hvac flared. 
  • ACCESSORIES: Electric Heat Packages EHKMA05KN, EHKMA10KN, HKMA15KN, EHKMA20KN (*Optional & Requires Separate 208-230V Power)

    FEATURES
  • Modes: Cool, Heat, Dry, Fan, Auto 
  • Multi Poise Installation (Up Flow, Down Flow, Horizontal Right, Horizontal Left)
  • Total system static pressure up to 0.8 in. W.C
  • Less than 2% air leakage
  • Quiet indoor operation 
  • Anti-corrosive fin coating
  • Extreme heating operation in as low as -22° F (-30° C)  
  • Optional Electric Heat Packages available (5, 10 KW)
  • Built-in third-party thermostat compatibility (Single Stage)


DLFSA Central Ducted
Heat Pump
System
Size 24
Indoor Model DLFSAAH24XAK 
Electrical
Voltage-Phase-Cycle V-Ph-Hz 208/230-1-60
Power Supply *Indoor unit powered from outdoor unit
MCA A. 5
Operating Range
Cooling Indoor DB Min - Max ° F (° C) 62~90 (17~32)
Heating Indoor DB Min - Max ° F (° C) 32~86 (0~30)
Piping
Pipe Connection Size - Liquid in (mm) 3/8 (9.52)
Pipe Connection Size - Suction in (mm) 5/8 (16)
Indoor
Unit Width in (mm) 19.6 (498)
Unit Height in (mm) 48.8 (1240)
Unit Depth in (mm) 21 (533)
Net Weight lbs (kg) 141.1 (64)
Number of Fan Speeds 4
Airflow (lowest to highest) CFM 588/765/882
Sound Pressure (lowest to highest) dB(A) 37.2/40.4/43/45.2
Max. Static Pressure in (WG) 0.8
Field Drain Pipe Size O.D. in (mm) 3/4 (19.1)





   